- [ 8 Eight Channel
Temperature Logger -
SmartReader 8 ]
- [ Data Logger & Software
Packages ]
- [ Display STARLOGGER
Model 6004-2 ]
- [ Eight-Channel Tempe-
rature Info Logger -

SmartReader Plus 8 ]
- [ Electric Current and
Temperature Info Logger
- SmartReader Plus 3 ]
- [ Electric Current and
Temperature Logger -
SmartReader 3 ]
- [ Hygro-Thermometer
Anemometer/Data Logger ]
- [ MACRO Data Logger
Model 7000 ]
- [ MACRO Tester model
7805A ]
- [ Memory Card STAR
LOGGER Model 6004-3 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader 6 ]
- [ Multi-channel Thermo-
couple Info Logger -
SmartReader Plus 6 ]
- [ Pressure, Temperature
and RH Info Logger -
SmartReader 4 ]
- [ Pressure, Temperature,
and RH Info Logger -
SmartReader Plus 4 ]
- [ Process Signal Info
Logger - SmartReader
Plus 7 ]
- [ Process Signal Logger -
SmartReader 7 ]
- [ Pulse Info Logger -
SmartReader Plus 9 ]
- [ Pulse Logger - Smart-
Reader 9 ]
- [ RF Remote Site
Monitoring Products ]
- [ Rugged MS-DOS 5.0
Hand-Held PC ]
- [ Standard STARLOGGER
Model 6004-1 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader 2 ]
- [ Temperature and Rela-
tive Humidity Logger -
SmartReader Plus 2 ]
- [ Temperature Info
Logger - SmartReader
Plus 1 ]
- [ Temperature Logger -
SmartReader 1 ]
- [ Thermocouple Info
Logger - SmartReader
Plus 5 ]
- [ Thermocouple Logger -
SmartReader 5 ]

Thermocouple Info Logger - Smart Reader Plus 5
Smart Reader Plus model 5 provides easy and accurate temperature recording from J, K, S, and T type thermocouples. 12 bits resolution increases the accuracy over the full range of the compatible thermocouples.

Applications : Monitoring performance of gas-fired heating equipment; verifying concrete curing temperatures, process verificastion, quality control in manufacturing.

Accessories : J, K, S, and T type Thermocouples.

Specifications :

  • No. of Channels : Three. (One internal thermistor for cold-junction compensation and 2 thermocouple inputs)
  • Accuracy : +/-0.5% of range + resolution.
Thermocouple Type Range Resolution
J -50 to 600°C
(-55 to 1100°F)
0.30°C (0.55°F)
K -100 to 900°C
(-145 to 1650°F)
0.50°C (0.90°F)
S 0 to 1450°C
(32 to 2642°F)
1.0°C (1.8°F)
T -200 to 400°C
(-325 to 750°F)
0.40°C (0.75°F)

Common Specifications :

  • Size : 107 x 74 x 22 mm (4.2" x 2.9" x 0.9")
  • Weight : 110 grams (3.75 ounces)
  • Case Material : Noryl Plastic
  • Operating Limits : -45°C to 70°C (-50°F to 160°F) and 0 to 95% Relative Humidity (non-condensing)
  • Clock-Accuracy : +/-2 seconds per day plus one sampling interval
  • Battery : 3.6 volt Lithium, 1 Amp-Hour
  • Power Consumption : 5 to 10 microamps (continuous)
  • Battery Life : Ten years (Factory Replaceable)
  • External Connector : Removable screw-type terminal strip with Common (-) connection
  • Memory Size : 21,500 readings
  • Sampling Methods :
    1. Continuous (First-in, First-out)
    2. Stop when full (Fill-then-stop)
  • Sampling Rates : User selectable rates from 25 per second to every 8 hours. (BP-100 battery pack required for sample rates less than 8 seconds)
  • Resolution : 12 bits (1 part in 4096)
  • PC Hardware Requirements : IBM PC or 100% compatible with: at least one free serial port;
  • Software Requirements : TrendReader for Windows-Windows version 3.1 or later already running with at least 2MB of RAM memory and 2MB of hard drive disk space
  • Product Approvals : Meets Part 15 for Digital Devices of the Code of Federal Regulations of the Federal Communications Commission (FCC). Meets Class A radiated and conducted emission requirements of Section 2 of the Radio Interference Regulations of Communications Canada. IEC801-2, 3, 4 and EN55011 covering ESD, RFI Immunity, EFT/Burst and Radiated Emmisions repectively for the Commision of the European Communities (CE).
  • Resistance to X-Rays : Tested for protection against a 160kV dose @ 5mA for 30 seconds (150mA-sec) @ 38 inches F.F.D. (about 100 times that of an airport X-Ray machine). Tested for protection against Gamma Ray (equivalent to 0.137 - 1.38 mega volts) IR 192 - 28 curies @ 30 second exposure source to object distance 5"

Internal Temperature Sensor (common on all models):

  • Type : Negative Temperature Coefficient Thermistor.
    10,000 ohms @ 25°C (77°F).
  • Tolerance (sensor only) : +/-0.2°C, over the range of 0 to 70°C (+/-0.3°F, over the range of 32 to 158°F).
  • Range : -40 to 70°C (-40 to 158°F)
  • Resolution : 0.03°C (0.05°F) at 25°C (77°F).
    Better than 0.07°C (0.12°F) between -25°C (-13°F) and 70°C (158°F).
    Better than 0.13°C (0.23°F) between -40°C (-40°F) and -25°C (-13°F).
CAT. NO.
_
DESCRIPTION
_
ACRSRP-005............. Thermocouple Logger, 128K
ACRTR-WIN-SRP.... TrendReader includes everything needed to access information from any 12 bit SRP logger Windos version

Temperature-Thermocouple Sensor :

CAT. NO.
_
DESCRIPTION
_
ACRTCJ-WELD........... J Type Welded Tip (1 foot section)
ACRTCK-WELD.......... K Type Welded Tip (1 foot section)
ACRTCT-WELD.......... T Type Welded Tip (1 foot section)
ACRTCJWIRE.............. J Type Bulk Wire
ACRTCKWIRE............ K Type Bulk Wire
ACRTCJWIRE.............. J Type Bulk Wire